- Trek Manuals
- Operator's manual
Trek 156A Operator's Manual
- page of 42 Go / 42
Table of Contents
- Safety Precautions for the Model 156A
Section I Introduction
- General Information
- Modes of Operation
- Incoming Inspection
- Incoming Confidence Test
Section II Installation
- Battery Operation
- Battery Charger/Eliminator Connection
- Initial Setup Connections
Section III Operation
- Front Panel Features
- Rear Panel Features
- Float Mode Operation
- Decay Mode Operation
- Programming the START Voltage
- Programming the STOP Voltage
- Monitoring the Plate Voltage Using the Output Monitor
Section IV Specifications
- Specifications
Section V Maintenance
- Battery Pack Maintenance
- Preventative Maintenance
- Customer Service Assistance
- Service Information
Advertisement
Quick Links
- 1 General Information
- 2 Modes of Operation
- 3 Initial Setup Connections
- 4 Float Mode Operation
- 5 Programming the Start Voltage
- 6 Programming Operation
- 7 Specifications
- Download this manual
Summary of Contents for Trek 156A
- Page 1 OPERATOR’S MANUAL MODEL 156A CHARGED-PLATE MONITOR 上海汇分电子科技有限公司 上海市闸北区天目西路511号锦程大厦1408室 联系方式:400-660-9565 网站:www.19mro.com 1445/JRB...
- Page 3 Thank you for buying a Trek instrument. This instrument has been designed and built to high standards to give you years of trouble-free service. If you have any questions, please feel free to contact your Trek Representative at: Write: TREK, INC.
Page 5: Table Of Contents
- Page 6 Section V Maintenance Safety Precautions for the Model 156A ..... . Battery Pack Maintenance ......
Page 7: Safety
- Page 8 Safety Safety Precautions (cont.) Indoor Use Only This instrument is intended for indoor use only. Do Not Operate in Wet or Damp Conditions To avoid electric shock, do not operate this instrument in wet or damp conditions. Do Not Operate in an Explosive Environment To avoid injury or fire hazard, do not operate this instrument in an explosive environment.
- Page 9 Safety Safety Terms and Symbols Terms in the Manual These terms may appear in this manual: Warning: Warning statements identify conditions or practices that could result in injury or loss of life. Caution statements identify conditions or practices that could result in Caution: damage to this product or other equipment.
Page 10: Safety Precautions For The Model 156A
Page 11: preface.
- Page 12 viii...
Page 13: Section I Introduction
Page 14: modes of operation, page 15: incoming confidence test.
- Page 16 STOP voltage’ on page III-5 for information on changing the decay stop voltage.) At the programmed stop voltage the decay timer will stop and the decay time will be indicated on the DECAY TIME display. This completes the incoming confidence test. Turn OFF the 156A. I - 4...
Page 17: Section Ii Installation
Page 18: initial setup connections, page 19: section iii operation, page 20: front panel features, page 21: rear panel features, page 22: float mode operation, page 23: programming operation, page 24: programming the stop voltage, page 25: monitoring the plate voltage using the output monitor.
- Page 26 III -8...
- Page 27 Section IV Model 156A Specifications DANGER: This instrument is not rated for use in an explosive environment. DO NOT use it an explosive environment or an explosion may result. PERFORMANCE Monitored Voltage Range 0 to ±1100 V DC or peak AC.
Page 28: Section Iv Specifications
- Page 29 Specifications Specifications (cont.) FEATURES (cont.) 3 ½ digit red LED display. Plate Voltage Digital Panel Meter Range 0 to ±1100 V. Resolution 1 volt. Better than 0.1% of full scale, ±1 count. Accuracy Decay Time Digital Panel Meter 4-digit red LED display. Range 0 to 9999 seconds.
- Page 30 Specifications (cont.) GENERAL Power Requirements Battery Eliminator/Charger Optionally available for all nominal line voltages. Contract Trek, Inc. or an authorized service organization for more information. NOTE: If line impulses exceed 500 V when using the battery eliminator/charger, the unit may reset and require operator...
- Page 31 Specifications Specifications (cont.) MECHANICAL Instrument Dimensions 83 mm H x 318 mm W x 280 mm D (3.25" H x 12.5" W x 11" D). Instrument Weight 2 kg (4.4 lb). Voltage Monitor Connector BNC coaxial connector. (3 meter length, maximum.) Ground Receptacle Banana jack.
- Page 32 Specifications Specifications (cont.) Certification and Compliance TREK, INC. certifies that each Certification Model 156A is tested and calibrated to specifications using measurement equipment traceable to the National Institute of Standards and Technology or traceable to consensus standards. A Certificate of Calibration accompanies each instrument when it is shipped from the factory.
Page 33: Section V Maintenance
Page 34: battery pack maintenance, page 35: service information.
- Page 37 Model 156P C25x25-S3M (1 x 1 ) ....17375 SPECIAL PLATES Contact TREK, INC. or an authorized sales organization for applications that require a different size or shape ion collecting plate.
- Page 39 Appendix B Warranty Statement New instruments sold by TREK, INC. (hereinafter called the “Company”) are warranted only as stated below: Subject to the exceptions and upon the conditions specified below, the Company agrees to correct, either by repair, or in the Company’s sole discretion, by replacement, any defect of...
- Page 41 Please go to our web site: www.trekinc.com for a complete list of our sales and service representatives and distributors located in the United States and throughout the world. Trek Contact Information: TREK, INC. 190 Walnut Street Lockport, NY 14094-3710 USA...
- Page 42 上海汇分电子科技有限公司 上海市闸北区天目西路511号锦程大厦1408室 联系方式:400-660-9565 网站:www.19mro.com...
Rename the bookmark
Delete bookmark, delete from my manuals, upload manual.
- {{>productsMenu}} Products
- {{>trendsMenu}} News & Trends
- Catalogs >
- TREK, INC. >
- News & Trends
- Exhibitions
156A 2 Pages
Catalog excerpts
Trek Model 156 ACharged Plate Monitor The Model 156A Charged-Plate Monitor is an important tool for evaluating the performance of air ionizers used to neutralize static charges. The Model 156A tests the efficiency of an ionizer’s ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre-charged to either a positive or negative value. The Model 156A also tests the balance between positive and negative air ions by measuring the offset voltage generated on a floating plate due to an imbalance of positive and negative air ions impinging on the plate from the ionizer. Typically, as an ionizer ages, the rates of positive and negative air ion production decline. Consequently, the time required for the ionizer to neutralize static charges increases, and the balance of positive and negative air ions changes. The neutralization (decay) time may become too long for the ionizer to fully neutralize charges that are generated at a work location, or the ionizer may begin to charge objects that were initially uncharged. Key Specifications • Large Signal Bandwidth: • Decay Mode Thresholds: Start/Stop Voltages Start/Stop Accuracy DC to 10 Hz Programmable from 1 to ±1000 V in 1 V increments Within ±1 V of programmed voltage Typical Applications Include • ESD monitoring of sensitive manufacturing processes such as semiconductor, disk drive and LCD • Testing of all types of ionizers, including room ionization systems, AC and DC blowers, nuclear ionizers, gun type ionizers, and pulsed DC ionizers • High temperature applications • ESD measurement of de-ionized water • Dissipative testing applications Features and Benefits • Customizable measurement capacitance provides assurance that ESD process needs are met in manufacturing and that there is compliance to ANSI/ESD-STM3.1 and IEC 61340-5-1. • Extremely low offset and drift ensures high accuracy, making it ideal for applications requiring critical ion balance such as GMR and TMR manufacturing areas • Compact and lightweight, for easy portability within a facility . NIST-traceable Certificate of Calibration provided with each unit . compliant TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK 716-438-7555 • 585-201-1804 (fax) • www.trekinc.com • sales@trek
Performance Monitored Voltage Range Large Signal Bandwidth Small Signal Bandwidth (-3dB) 0 to ±1100 V DC or peak AC DC to 10 Hz (measured at 2000 V p-p) DC to 1 kHz (measured at 20 V p-p) Zero Stability (referred to plate voltage) Drift with Time (no incident Less than 6 V/minute ion flow) Drift with Temperature Less than 10 mV/°C, noncumulative Decay Mode Thresholds Start Voltage Programmable from 1 to ±1000 V in 1 V increments Stop Voltage Programmable from 0 to ±999 V in 1 V Start/Stop Accuracy Within ±1 V of programmed voltage Discharge Time 0.1 seconds, from 0.1 to 999.9...
All TREK catalogs and technical brochures
2 Pages
1 Pages
4 Pages
16 Pages
9 Pages
Related Searches
- Power supply
- AC/DC power supply
- Measuring device
- Switching power supply
- Single-output power supply
- Optical microscope
- Signal amplifying integrated circuit
- Digital gauge
- Variable-output power supply
- Portable gauge
- DC/DC power supply
- Programmable power supply
- Power amplifying integrated circuit
- Desktop microscope
- Measuring microscope
- Rack-mount power supply
- Regulated power supply
- Tabletop power supply
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
- Trek Manuals
Trek 156A Manuals & User Guides
User Manuals, Guides and Specifications for your Trek 156A Monitor. Database contains 1 Trek 156A Manuals (available for free online viewing or downloading in PDF): Operator's manual .
Trek 156A Operator's manual (42 pages)
Pages: 42 | Size:
Trek 156A Related Products
- Siko MA503/2
- Pioneer PDP-5050HD
- SuperLogics PPC-360
- Palsonic TFTV201
- Samsung Electronics OM24E
- ViewSonic PD1631T
- Hussmann Chino SHVSS-S/C
- LG W2253V W2353V
Trek 156A Monitor: Frequently-viewed manuals
- Mitsubishi Electric
- Alliance Laundry Systems
- Samsung Electronics
- Air Conditioner
- Indoor Furnishing
- Kitchen Appliances
- Refrigerator
- Measuring Instruments
- Control Unit
- My Downloads 187205
- Account Settings
- How it Works
- Questions and Suggestions
- Bicycle Computer
Trek 156A User Manual
Charged-Plate Monitor
Is your ionizer neutralizing charges as quickly and completely as needed?
Is the ion output balanced?
Can you evaluate your ionizers while they are installed in production?
Is the recording of your ionizer test data
efficient and cost effective?
Importance of Ionization Monitoring
The Trek Model 156A Charged-Plate Monitor will enable you to confidently answer the above questions so that you can effectively monitor and maintain your ionization program.
· Use the Model 156A to verify that new ionizers meet your selection criteria.
· When evaluating newly setup or active ionizer installations, use the Model 156A to determine if the decay times and ion balance performance are satisfactory for your application.
· Use the compact and portable Model 156A to determine when an ionizer needs maintenance.
The Model 156A Charged-Plate Monitor is an important tool for evaluating the performance of the air ionizers used to neutralize static charges.
Trek offers the Model 156A/1 with a computer interface option. This option adds both a serial communications port and an applications software program to operate, analyze, and save data from the charged-plate monitor to a computer.
The Model 156A tests the efficiency of your ionizer’s ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre-charged to either a positive or negative value. The Model 156A also tests the balance between positive and negative air ions by measuring the offset voltage generated on a floating plate due to an imbalance of positive and negative air ions impinging on the plate from your ionizer.
Typically, as the ionizer ages, the rates of positive and negative air ion production decline. Consequently, the time required for the ionizer to neutralize static charges increases, and the balance of positive and negative air ions changes.
The neutralization (decay) time may become too long for the ionizer to fully neutralize charges that are generated at a work location, or the ionizer may begin to charge objects that were initially uncharged.
By using the Model 156A to periodically measure the decay times and the ion balance, the need for, and frequency of, ionizer preventative maintenance can be easily determined.
Measurement and Power Solutions TM
www.trekinc.com
Charged Plate Monitor - Model 156A
Trek model 156a.
The Model 156A Charged-Plate Monitor is an important tool for evaluating the performance of air ionizers used to neutralize static charges. The Model 156A tests the efficiency of an ionizer’s ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre-charged to either a positive or negative value. The Model 156A also tests the balance between positive and negative air ions by measuring the offset voltage generated on a floating plate due to an imbalance of positive and negative air ions impinging on the plate from the ionizer.
- ESD monitoring of sensitive manufacturing processes such as semiconductor, disk drive and LCD.
- Testing of all types of ionizers, including room ionization systems, AC and DC blowers, nuclear ionizers, gun type ionizers, and pulsed DC ionizers.
- High temperature applications.
- ESD measurement of de-ionized water.
- Dissipative testing applications.
Specifications:
- Company Profile
- Competencies
- Milestones & Achievements
- Affiliations
- Sustainability
- Branches Contacts
- Legal Notices
Find manuals by category
Bike manuals.
- E-bike manuals
Suspension setup guides
- Computer owner’s manuals
Light manuals
- Tube, tire & wheel manuals
Brakes manuals
Pump manuals, helmet manuals, shoe manuals, handlebar manuals, seatpost manuals, bicycle rack manuals.
- Lubricant and solvents manuals
- Lock manuals
Accessories
Some products listed on this page may be available only in select markets. Please refer to your local Trek retailer to confirm availability and date of release in your country or region.
Trek Bicycle owner’s manual
This bike manual comes standard on most makes and models of Trek bikes.
- Supplemental info: Stems
- Supplemental info: Tools
- Supplemental info: Riding Tips
- Supplemental info: Fitting Your Bicycle
- Supplemental info: Mechanical Warning
- Supplemental info: Lubrication
- Supplemental info: Torque
Additional Trek bicycle manuals
2024 bike manuals and guides, 2023 bike manuals and guides, 2022 bike manuals and guides, 2021 bike manuals and guides, 2020 & older bike manuals and guides, gary fisher, electric bikes.
- 2009+ suspension setup calculator
- Suspension setup video (youtube)
Computer manuals
Bontrager computers, trek computers, current product manuals, previous generation manuals, tube, tire, and wheel manuals, lubricants, solvents and touch-up paint, lock manuals.
Trek 156A Charged Plate Monitor User Manual
- Original mode
Model 10/40A Specifications
Model 156A Specifications
Model 156A and 156A/1 Ordering Information
Copyright © 2011 TREK, INC.
All specifications are subject to change.
Included Accessories
Optional Accessories
Ion Collecting Plates
Charge Plate Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . Model 156A
Operator’s Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23126
Charge Plate Monitor with serial interface . . . . . . . . . Model 156A/1
PC Compatible Computer Software (156A/1 only) . . . . . . . . . . . 43267 Banana to Banana Stackable Cord (9 ft.) . . . . . . . . . . . . . . . . . . N9044
Battery Eliminator/Charger (115 V AC) . . . . . . . . . . . . . . . . . . . . L5111
Standard Plates (ordered separately)
Universal AC Adapter Kit (100 to 240 V AC) . . . . . . . . . . . . . . . . 1K010
15 cm x15 cm (6” x 6”) plate . . . . . . . . . . . . . . . . . . . . . . . . . . 17397
Ion Collecting Plate Tripod. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DK142
25 mm x 25 mm (1”x 1”) plate . . . . . . . . . . . . . . . . . . . . . . . . . 17375
Carrying Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43433
Special Plates (ordered separately) Custom plate sizes are available by special order.
Computer Requirements: Windows 9X or later, NT4, PC compatible
computer, 486DX66 or better, 16 Mb of RAM, and high speed serial port with 16550 or equivalent UART.
Performance
Features (cont.)
Monitored Voltage Range
Test/Reset Control (cont.)
Ion Collecting Plate (standard option)
0 to ±1100 V DC or peak AC.
+Decay and -Decay Modes
Small Signal Bandwidth (-3 dB)
Sets the plate voltage to a value greater
15 cm x 15 cm square, (6”x 6” square).
DC to 1 kHz (measured at 20 V p-p).
than the programmed start voltage and
Capacitance
Large Signal Bandwidth
resets the decay timer to zero.
20 pF ±2 pF.
DC to 10 Hz (measured at 2000 V p-p).
(Other capacitance options available)
Zero Stability (referred to plate voltage)
Sets the plate voltage to 0 V ±2 V.
Drift with Time (no incident ion flow)
Voltage Monitor Output
Less than 6 V/minute.
A BNC providing a low voltage replica of
Drift with Temperature
the plate voltage.
Less than 10 mV/°C, noncumulative.
Power Requirements
Scale Factor
Battery Eliminator/Charger
Decay Mode Thresholds
1/200th of the plate voltage.
Start Voltage
(ordered separately)
DC Accuracy
Unit and software programmable
Specifications
Better than 0.1% of full scale.
Output Connector
from 1 to ±1000 V in 1 V increments.
Offset Voltage
2.1 mm DC power plug.
Start Accuracy
Less than ±10 mV.
Output Voltage
Unit and Software within ±1 V of
Output Noise
12 to 14 V DC.
programmed start voltage.
Less than 10 mV rms (measured
Output Current
Stop Voltage
using the true rms feature of the
Hewlett Packard Model 34401A
Battery Operation
from 0 to ±999 V in 1 V increments.
digital multimeter).
Rechargeable battery, supplied.
Stop Accuracy
Output Impedance
Operating Time
Less than 0.1 W.
8 hours from a full charge (156A).
programmed stop voltage.
Plate Voltage Digital Panel Meter
Recharge Time
Plate Self-Discharge (unpolarized)
3 ½ digit red LED display.
3 hours to full charge.
Less than 12 V/minute.
0 to ±1100 V.
Low battery indicator.
Full charge indicator.
Operating Conditions
Mode Select
Temperature
Better than 0.1% of full scale ±1
A three-position toggle switch selects the
5 °C to 35 °C.
+Decay, -Decay, or Float mode of
Relative Humidity
Decay Time Digital Panel Meter
operation. This switch is also used in
To 80%, noncondensing.
4-digit red LED display.
combination with the Test/Reset Control
Instrument Dimensions
switch to program the START and STOP
83 mm H x 318 mm W x 280 mm D,
0 to 9999 seconds.
(3.25" H x 12.5" W x 11" D).
Test/Reset Control
Instrument Weight
0.1 seconds, from 0.1 to 999.9
A momentary toggle switch used in
Approx. 2 kg (4.4 lb).
seconds; 1 second, from 1000 to
conjunction with the Mode Select switch
9999 seconds. (The display will
The Model 156A and 156A/1 are
to program the START and STOP voltages.
indicate “- - - -” when the decay time
CE Compliant
exceeds 9999 seconds.)
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
(fax) • www.trekinc.com • [email protected]
716-438-7555 • 716-201-1804
- Canon - AE-1
- Fitbit - Flex
- Nikon - D5000
- Nikon - D40
- Nikon - D3100
- Nikon - D90
- Nikon - D7000
- Nikon - D80
- Nikon - D3000
- HP - Officejet Pro 8600
- Canon - EOS 60D
- HP - 12C Financial calculator
Free Shipping on Most Simco-Ion Products!
- (805) 658-0207
- [email protected]
- Case Studies
- Applications
Trek 156A Charge Plate Monitor
Call for Price
Charge Plate Monitor for Evaluating the Performance of Air Ionizers Used to Neutralize Static Charges
Advanced Energy’s Trek 156A tests the efficiency of an ionizer’s ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre-charged to either a positive or negative value.
- Monitored Voltage Range: 0 to ±1100 VDC or peak AC
- Large Signal Bandwidth: (-3dB): DC to 10 Hz
- Decay Mode Thresholds: Programmable from 1 to ±1000 V in 1V increments (accurate within ±1V of programmed voltage)
CALL FOR MORE INFO AND PRICING!
[email protected] or 805-658-0207
The Trek ® 156A tests the efficiency of an ionizer’s ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre-charged to either a positive or negative value. The Trek 156A also tests the balance between positive and negative air ions by measuring the offset voltage generated on a floating plate due to an imbalance of positive and negative air ions impinging on the plate from the ionizer.
Typically, as an ionizer ages, the rates of positive and negative air ion production decline. Consequently, the time required for the ionizer to neutralize static charges increases, and the balance of positive and negative air ions changes. The neutralization (decay) time may become too long for the ionizer to fully neutralize charges that are generated at a work location, or the ionizer may begin to charge objects that were initially uncharged.
- Set custom measurement capacitance for assurance that ESD process needs are met in manufacturing
- Easily transport within a facility with the compact and lightweight design
- Use for ESD monitoring of sensitive manufacturing processes such as semiconductor, disk drive, and LC
- Extremely low offset and drift ensures high accuracy, making it ideal for applications requiring critical ion balance such as GMR and TMR manufacturing areas
- NIST-traceable Certificate of Calibration provided with each unit
You May Also Be Interested In
ESD JACKET 8812, Lightweight/ Knit Cuff or Snap Cuff
Stamina, E3 Series ESD Safe/Non-Cleanroom Task Chair Vinyl
Stamina, e3 series esd/non-cleanroom task chair fabric, stamina, ce3 series cleanroom/class 100/esd safe task chair vinyl, stamina, c3 series cleanroom/class 100 task chair vinyl.
Stamina, 3 Series Task Chair Standard Fabric
A name you can trust. Doing business since 1978!
- 4022 Camino Ranchero Unit B Camarillo, CA 93012
- Instrumentation
- Workstations
- METRO/Handling
- Trek Manuals
- Operator's manual
Trek 156A Operator's Manual
- page of 42 Go / 42
Table of Contents
- Safety Precautions for the Model 156A
Section I Introduction
- General Information
- Modes of Operation
- Incoming Inspection
- Incoming Confidence Test
Section II Installation
- Battery Operation
- Battery Charger/Eliminator Connection
- Initial Setup Connections
Section III Operation
- Front Panel Features
- Rear Panel Features
- Float Mode Operation
- Decay Mode Operation
- Programming the START Voltage
- Programming the STOP Voltage
- Monitoring the Plate Voltage Using the Output Monitor
Section IV Specifications
- Specifications
Section V Maintenance
- Battery Pack Maintenance
- Preventative Maintenance
- Customer Service Assistance
- Service Information
Quick Links
- 1 General Information
- 2 Modes of Operation
- 3 Initial Setup Connections
- 4 Float Mode Operation
- 5 Programming the Start Voltage
- 6 Programming Operation
- 7 Specifications
Summary of Contents for Trek 156A
- Page 1 OPERATOR’S MANUAL MODEL 156A CHARGED-PLATE MONITOR 上海汇分电子科技有限公司 上海市闸北区天目西路511号锦程大厦1408室 联系方式:400-660-9565 网站:www.19mro.com 1445/JRB...
- Page 3 Thank you for buying a Trek instrument. This instrument has been designed and built to high standards to give you years of trouble-free service. If you have any questions, please feel free to contact your Trek Representative at: Write: TREK, INC.
Page 5: Table Of Contents
- Page 6 Section V Maintenance Safety Precautions for the Model 156A ..... . Battery Pack Maintenance ......
Page 7: Safety
- Page 8 Safety Safety Precautions (cont.) Indoor Use Only This instrument is intended for indoor use only. Do Not Operate in Wet or Damp Conditions To avoid electric shock, do not operate this instrument in wet or damp conditions. Do Not Operate in an Explosive Environment To avoid injury or fire hazard, do not operate this instrument in an explosive environment.
- Page 9 Safety Safety Terms and Symbols Terms in the Manual These terms may appear in this manual: Warning: Warning statements identify conditions or practices that could result in injury or loss of life. Caution statements identify conditions or practices that could result in Caution: damage to this product or other equipment.
Page 10: Safety Precautions For The Model 156A
Page 11: preface.
- Page 12 viii...
Page 13: Section I Introduction
Page 14: modes of operation, page 15: incoming confidence test.
- Page 16 STOP voltage’ on page III-5 for information on changing the decay stop voltage.) At the programmed stop voltage the decay timer will stop and the decay time will be indicated on the DECAY TIME display. This completes the incoming confidence test. Turn OFF the 156A. I - 4...
Page 17: Section Ii Installation
Page 18: initial setup connections, page 19: section iii operation, page 20: front panel features, page 21: rear panel features, page 22: float mode operation, page 23: programming operation, page 24: programming the stop voltage, page 25: monitoring the plate voltage using the output monitor.
- Page 26 III -8...
- Page 27 Section IV Model 156A Specifications DANGER: This instrument is not rated for use in an explosive environment. DO NOT use it an explosive environment or an explosion may result. PERFORMANCE Monitored Voltage Range 0 to ±1100 V DC or peak AC.
Page 28: Section Iv Specifications
- Page 29 Specifications Specifications (cont.) FEATURES (cont.) 3 ½ digit red LED display. Plate Voltage Digital Panel Meter Range 0 to ±1100 V. Resolution 1 volt. Better than 0.1% of full scale, ±1 count. Accuracy Decay Time Digital Panel Meter 4-digit red LED display. Range 0 to 9999 seconds.
- Page 30 Specifications (cont.) GENERAL Power Requirements Battery Eliminator/Charger Optionally available for all nominal line voltages. Contract Trek, Inc. or an authorized service organization for more information. NOTE: If line impulses exceed 500 V when using the battery eliminator/charger, the unit may reset and require operator...
- Page 31 Specifications Specifications (cont.) MECHANICAL Instrument Dimensions 83 mm H x 318 mm W x 280 mm D (3.25" H x 12.5" W x 11" D). Instrument Weight 2 kg (4.4 lb). Voltage Monitor Connector BNC coaxial connector. (3 meter length, maximum.) Ground Receptacle Banana jack.
- Page 32 Specifications Specifications (cont.) Certification and Compliance TREK, INC. certifies that each Certification Model 156A is tested and calibrated to specifications using measurement equipment traceable to the National Institute of Standards and Technology or traceable to consensus standards. A Certificate of Calibration accompanies each instrument when it is shipped from the factory.
Page 33: Section V Maintenance
Page 34: battery pack maintenance, page 35: service information.
- Page 37 Model 156P C25x25-S3M (1 x 1 ) ....17375 SPECIAL PLATES Contact TREK, INC. or an authorized sales organization for applications that require a different size or shape ion collecting plate.
- Page 39 Appendix B Warranty Statement New instruments sold by TREK, INC. (hereinafter called the “Company”) are warranted only as stated below: Subject to the exceptions and upon the conditions specified below, the Company agrees to correct, either by repair, or in the Company’s sole discretion, by replacement, any defect of...
- Page 41 Please go to our web site: www.trekinc.com for a complete list of our sales and service representatives and distributors located in the United States and throughout the world. Trek Contact Information: TREK, INC. 190 Walnut Street Lockport, NY 14094-3710 USA...
- Page 42 上海汇分电子科技有限公司 上海市闸北区天目西路511号锦程大厦1408室 联系方式:400-660-9565 网站:www.19mro.com...
- MyAE Dashboard
- My Order History
- Stock Check
- Online Order Support
- How to Order Online
Trek 157 Series
Charged plate monitor that offers better accuracy, stability, and bandwidth than conventional designs.
- Greater bandwidth enables “true” responses to be observed by avoiding the masking of results
- Extremely low offset and drift ensures high accuracy, making it ideal for applications requiring critical ion balance such as GMR and TMR manufacturing areas
- NIST-traceable Certificate of Calibration provided with each unit
- Set custom measurement capacitance for assurance that ESD process needs are met in manufacturing
- Easily transport within a facility with the compact and lightweight design
- Use for ESD monitoring of sensitive manufacturing processes such as semiconductor, disk drive, and LCD
Specifications
Technical documentation, accessories.
Charge Plate Monitor Accessories
Accessories compatible with the Monroe and Trek charge plate monitors.
- Monroe 287 CPM Plate Adapter Data Sheet (834 KB)
- Trek 156A and 157 CPM Accessories Data Sheet (648 KB)
Calibration and Alignment
Advanced Energy has the tools and processes to ensure your equipment continues to meet its original specifications. Our products are calibrated at global AE service sites with proprietary technology designed to exceed industry standards.
24/5 Support Available
Get expert advice from our engineers.
To use live chat, we need your consent to functional cookies by clicking the button below. You can find more information about our privacy policy here .
By clicking "I agree" below, you are sharing your data with Advanced Energy Industries and Mouser, our supplier direct third-party distribution partner. You will be transferred to the supplier direct site to complete this transaction.
IMAGES
VIDEO
COMMENTS
Cycling of the battery pack can be accomplished by following the procedure below. 1) Plug the battery eliminator/charger into the Model 156A. 2) Charge the battery pack until the "Full Charge" indicator on the Model 156A is illuminated. 3) Remove the charger from the Model 156A.
The Trek® 156A tests the efficiency of an ionizer's ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre-charged to either a positive or negative value. The Trek 156A also tests the balance between positive and negative air ions by measuring the offset voltage generated on a floating ...
The Trek ® 156A tests the efficiency of an ionizer's ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre-charged to either a positive or negative value. The Trek ® 156A also tests the balance between positive and negative air ions by measuring the offset voltage generated on a floating plate due to an imbalance of positive and ...
Trek 156A Operator's Manual. Trek 156A Charged-Plate Monitor provides quantitative and accurate measurements for air ionization tests. It offers negative (-) and positive (+) decay modes, float mode operation, and programming of the START and STOP voltages. The buffered output provides a low-voltage replica of the voltage on the ion collecting ...
The Model 156A is powered by an internal rechargeable battery that offers 8 hours of operation from a full charge. The Trek Model 156A/1 has a serial interface port to connect with a computer. Computer. Software allows the operator to program test sequences, save, or retrieve test results. Any series of tests can be duplicated, analyzed ...
The Trek Model 156A Charged-Plate Monitor will. The Model 156A tests the efficiency of your. enable you to confidently answer the above. ionizer's ion production by timing how long it. questions so that you can effectively monitor and. takes air ions produced to discharge a floating. maintain your ionization program.
Trek Model 156 ACharged Plate Monitor The Model 156A Charged-Plate Monitor is an important tool for evaluating the performance of air ionizers used to neutralize static charges. The Model 156A tests the efficiency of an ionizer's ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre ...
Trek Model 156A Charged Plate Monitor Typical Applications Include! ESD monitoring of sensitive manufacturing processes such as semiconductor, disk drive and LCD! ... TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK 716-438-7555 • 585-201-1804 (fax) • www.trekinc.com • [email protected] ...
Trek 156A Manuals & User Guides. User Manuals, Guides and Specifications for your Trek 156A Monitor. Database contains 1 Trek 156A Manuals (available for free online viewing or downloading in PDF): Operator's manual .
The Trek Model 156A Charged-Plate Monitor will enable you to confidently answer the above questions so that you can effectively monitor and maintain your ionization program. · Use the Model 156A to verify that new ionizers meet your selection criteria. · When evaluating newly setup or active ionizer installations, use the Model 156A to ...
Trek Model 156A Download File Product Enquiry. Features: The Model 156A Charged-Plate Monitor is an important tool for evaluating the performance of air ionizers used to neutralize static charges. The Model 156A tests the efficiency of an ionizer's ion production by timing how long it takes air ions produced to discharge a floating plate that ...
2023 Bike manuals and guides. Service manual - 2023 Allant+ 5 / 6. Service manual - 2023 Domane SL / SLR Gen. 4. Service manual - 2023 Domane+ AL. Service manual - 2023 Domane+ SLR. Service manual - 2023 Emonda ALR. Service manual - 2023 Farley Alloy. Service manual - 2023 Farley Carbon. Service manual - 2023 Fetch+ 2.
Read online or download PDF • Page 2 / 2 • Trek 156A Charged Plate Monitor User Manual • Trek Equipment. Manuals Directory ManualsDir.com - online owner manuals library. Search. Directory. Brands. Trek manuals. Equipment. 156A Charged Plate Monitor ... The Model 156A and 156A/1 are. to program the START and STOP voltages. indicate ...
Low Profile Charged Plate. Trek 156P-LP Low Profile Charged Plate provides a design used for ESD monitoring of sensitive manufacturing processes in tight spacing situations. The thin plate is under 7 mm in height, light-weight and can be hand-. held for easy transport. Trek 156P-LP. Ideal for monitoring static charge in a manufacturing facility.
The Trek ® 156A tests the efficiency of an ionizer's ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre-charged to either a positive or negative value. The Trek 156A also tests the balance between positive and negative air ions by measuring the offset voltage generated on a floating plate due to an imbalance of positive and negative ...
Trek Model 156A Charged Plate Monitor Typical Applications Include! ESD monitoring of sensitive manufacturing processes such as semiconductor, disk drive and LCD! ... TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK 716-438-7555 • 585-201-1804 (fax) • www.trekinc.com • [email protected] ...
Trek ESD Measurement & Control Instruments - Table of Contents *Note: Trek products are not rated for use in an explosive atmosphere. www.trekinc.com 1 Model 520-1, Model 876 AC Feedback Electrostatic Voltmeters ... Ion Collecting Plates (can be used with Model 156A and 157) Dimensions.....31.8cm W x 8.3cm H x 28.0cm D ...
The Trek ® 158A charged plate monitor is the premier instrument to evaluate the performance of air ionization systems. It features a user-friendly large 7-inch screen that is active through either touch-screen control or corresponding function keys.
Page 33: Section V Maintenance. Cycling of the battery pack can be accomplished by following the procedure below. 1) Plug the battery eliminator/charger into the Model 156A. 2) Charge the battery pack until the "Full Charge" indicator on the Model 156A is illuminated. 3) Remove the charger from the Model 156A.
<body bgcolor="#FFFFFF"> Please visit <a href="https://www.advancedenergy.com/landing-pages/trek-and-monroe-ae-product-lines//products/eosesd/156a.htm">this link</a ...
The Trek ® 157 combines patented precision charge measurement capability with features that drive down ionizer maintenance and performance testing costs. Enhanced features, such as those that enable the operator to store and retrieve data as data points or graphs and record operator comments for reference, make the Trek ® 157 ideal for use in dissipative testing of materials and monitoring ...